RADRESPONSE

Home       Customer Support       Resource Center      Corporate Partners       About Us

A. 793 mR/hr is correct

 

                                        Detector Exposure Rate  X  (Detector Distance)2

Entry Exposure Rate = —————————————————————-

                                                             (Entry Activity Distance)2

 

 

 

                                                          0.1 mR/hr  X  (178 feet)2

Entry Exposure Rate = —————————————————————-

                                                                     (2 feet)2

 

 

 

                                                          0.1 mR/hr  X  31,684 feet2

Entry Exposure Rate = —————————————————————-

                                                                     (2 feet)2

 

 

 

                                                              3168.4 mR/hr feet2

Entry Exposure Rate = —————————————————————-

                                                                     (2 feet)2

 

 

 

                                                                   3168.4 mR/hr feet2

Entry Exposure Rate = —————————————————————-

                                                                          4 feet2

 

 

 

Entry Exposure Rate = 792.1 mR/hr

 

Entry Exposure Rate = 793 mR/hr

 

 

 

Click your browser “BACK” button to continue with the scenario.